Bev, I think this looks good to me. -----Original Message----- From: TechNet [mailto:[log in to unmask]] On Behalf Of Bev Christian Sent: Thursday, August 06, 2009 11:35 AM To: [log in to unmask] Subject: [TN] Let's try this again - Underfill Workmanship TechNetters, I put out to you last week a newer version of the document we had put together on the above titled subject. I did not receive a single comment back, either on or off line from TechNetters. :( I am trying again. There are some additions but also some changes because I had had some grief that what was being asked for in the previous version was not always attainable. Changes are in capitals, since TechNet can't show colors or italics. The creep of solder into connecting voids has been argued to not be a high level concern where: 1) the product use temperature is less than 50C 2) the product has a practical lifetime of about two years 3) The solder used is SAC305, not the lower melting SnPb eutectic. Hope this sparks a good technical discussion. It is not Friday yet. Bev RIM Workmanship Standards for BGA and CSP Underfills For general inspection of all circuit packs coming down a production line, apply only the portions of this document that can be performed visually to underfilled, uncovered CSPs and BGAs or those same types of components under fence and lid RF shields. The visual inspection rules do not apply to CSPs and BGAs for general production under single piece RF cans. This would require destruction of all product. However, all the rules apply for process development/product qualification where one is willing to sacrifice finished circuit packs to gain knowledge of the acceptability of the overall quality. Target - Class 1,2,3 * Component requiring underfill completely underfilled with a good fillet all the way around, the fillet just approaching the maximum component body height, completely cured, no encroachment onto other components and no voiding whatsoever Acceptable - Class 3 * At least 50% fillet height up the side of the component body * Small pin holes and voids are permissible provided they do not exceed 5% of fillet surface area and have a maximum diameter of 0.5 mm (0.020 inches). Acceptable - Class 1,2 * Component requiring underfill underfilled such that all balls are covered, but no evidence of an exterior fillet, no encroachment onto other components and no voiding whatsoever. * Component requiring underfill underfilled such that all balls are covered, with or without an exterior fillet, no encroachment onto other components and only small voids, not touching any solder joints. * Component requiring underfill underfilled such that all balls are covered, with or without an exterior fillet, no encroachment onto other components and even large voiding, but not touching any solder joints. * TOTAL VOID AREA, IRRESPECTIVE OF LOCATION, AS A PERCENTAGE OF COMPONENT AREA SHALL BE EQUAL TO OR LESS THAN 10%. * A VOID OR VOIDS LESS THAN OR EQUAL TO 50% AROUND THE PERIMETER OF ONE OR MORE SOLDER JOINTS, INCLUDING IN AN OUTER ROW. * VOIDS GREATER THAN 50% AROUND INNER ROW SOLDER JOINTS. * SOLDER JOINTS WITH VOIDS COMPLETELY SURROUNDING INDIVIDUAL SOLDER JOINTS AND/OR VOIDS CONNECTING TWO SOLDER JOINTS MAKE UP LESS THAN 10% OF THE TOTAL NUMBER OF SOLDER JOINTS OF THE COMPONENT. THIS RULE ONLY APPLIES TO INNER ROW SOLDER JOINTS (E). Defect - Class 3 * LESS THAN 50% FILLET HEIGHT UP THE SIDE OF THE COMPONENT BODY * SMALL PIN HOLES AND VOIDS EXCEEDING 5% OF FILLET SURFACE AREA AND/OR HAVE A MAXIMUM DIAMETER OF GREATER THAN 0.5 MM (0.020 INCHES). Defect - Class 1,2,3 * Underfill completely missing from components where it is required * Underfill not completely covering all the peripheral solder joints * Voiding such that a void traverses the distance between two or more OUTER ROW solder joints (DELETE under the array device requiring underfill) * A void or voids more than 50% around the perimeter of one or more OUTER ROW solder joints * Material extending on to the top of the BGA or CSP * Uncured material * Underfill interfering with proper placement of a heatsink or other mounted or mechanical devices or would interfere with the assembly * There should be no evidence of underfill flowing out through holes under the device. * After curing there should be no visual evidence of cracks between the device surface, underfill or board. * There should be no evidence of damage to the board or device caused by contact with the dispensing needle or height sensor. * Underfill filler shows evidence of separation Special Conditions - Class 1,2 * Encroachment onto other components, but meeting all other criteria above for target or acceptable conditions will be dealt with as a pass/fail on a case-by-case basis --------------------------------------------------------------------- This transmission (including any attachments) may contain confidential information, privileged material (including material protected by the solicitor-client or other applicable privileges), or constitute non-public information. Any use of this information by anyone other than the intended recipient is prohibited. If you have received this transmission in error, please immediately reply to the sender and delete this information from your system. Use, dissemination, distribution, or reproduction of this transmission by unintended recipients is not authorized and may be unlawful. --------------------------------------------------- Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815 ----------------------------------------------------- --------------------------------------------------- Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815 -----------------------------------------------------