Steve I installed the first immersion silver line in North America in 95. We built millions of boards with this finish and the only issue brought to my attention was exposure to a sulfur environment. Multiple reflows did not present an issue and we stored the boards at customer sites for over a year without a problem. Our customers did not find it necessary to use gloves in the assembly operation. Best regards Lee J. L. Parker Ph. D. JLP Consultants LLC 804 779 3389 ----- Original Message ----- From: Steve Kelly<mailto:[log in to unmask]> To: [log in to unmask]<mailto:[log in to unmask]> Sent: Tuesday, May 26, 2009 5:00 PM Subject: [TN] Immersion Silver Good Afternoon, Any concerns about using immersion silver as a finish. PWB has to take two reflow cycles, 1 re-work cycle and one hand solder after the two reflows. Parts have to be transported from one part of the country to another after the two reflows. Thanks. Steve Kelly Steve Kelly (PLEASE NOTE NEW E-MAIL ADDRESS) (416) 750-8433 (work) (416) 750-0016 (fax) (416) 577-8433 (cell) --------------------------------------------------- Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask]<mailto:[log in to unmask]> with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]<mailto:[log in to unmask]>: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]<mailto:[log in to unmask]>: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives<http://listserv.ipc.org/archives> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16<http://www.ipc.org/contentpage.asp?Pageid=4.3.16> for additional information, or contact Keach Sasamori at [log in to unmask]<mailto:[log in to unmask]> or 847-615-7100 ext.2815 ----------------------------------------------------- --------------------------------------------------- Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815 -----------------------------------------------------