Don't know of a actual coupon but Specimen E is the "Y" version. Testing for
clean boards/panels should be done prior to any soldermask adhesion or
conformal coating so you will pass any peel testing. I am sure most fab
house claim they have a known good profile of the process so they don't have
to verify each panel is clean.



www.quickturnflex.com
Thank you, 
Jim Mahoney 
Quick Turn Flex Circuits, LLC 
Applications Project Manager 
P# 603-821-7071
M# 603-305-6250 
** This email and all attachments have been scanned prior to being sent** 
Confidentiality Notice: This page and any accompanying documents contain
information that is confidential, privileged or exempt from disclosure and
is intended for the exclusive use of the addressee. If you are not the
intended recipient, you are hereby notified that any disclosure, copying,
distribution or use of the contents of this information in any manner is
strictly prohibited.


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Richard Kraszewski
Sent: Friday, May 15, 2009 10:25 AM
To: [log in to unmask]
Subject: [TN] Military Specification Y-pattern

I seen to recall the military used to call out a "Y" pattern as a basic
test for cleanliness. Possibly Mil std-202 or 883?  Does anyone recall
which document & ~section?
 
Rich  Kraszewski 
<mailto:[log in to unmask]> 
 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------