Amol - From what I had just over a year ago in Appendix E of J002C Appendix E: Informative Annex E.1 Test Equipment Sources The equipment sources described below represent those currently known to the industry. Users of this document are urged to submit additional source names as they become available, so that this list can be kept as current as possible. The equipment sources described below represent those currently known to the industry. Users of this document are urged to submit additional source names as they become available, so that this list can be kept as current as possible. E.1.1 Tests A, B, C, D, A1, B1, C1, D1 GEN3 Systems Limited (Formerly Concoat Systems) Unit B2, Armstrong Mall, Southwood Business Park, Farnborough, Hampshire GU14 0NR England. 011 44 12 5252 1500 www.gen3systems.com HMP Soldermatics, P.O. Box 948, Canon City, CO 81215, (719)275-1531 Malcomtech 26200 Industrial Blvd, Hayward CA 64545, 510-293-0580, www.malcomtech.com Reef Engineering, Unit 6, Bancrofts Road, South Woodham Ferrers, Essex CM3 5UQ 01245 328123 Robotic Process Systems, 23301 E. Mission Ave., Liberty Lake, WA 99019, (509)891-1680 E.1.2 Tests E & F, E1 & F1 Convey AB, Harpsundsvagen 113, S-12458 Bandhagen, Sweden 46 (0) 8 99 66 25 GEN3 Systems Limited (Formerly Concoat Systems) Unit B2, Armstrong Mall, Southwood Business Park, Farnborough, Hampshire GU14 0NR England. 011 44 12 5252 1500 www.gen3systems.com Malcomtech 26200 Industrial Blvd, Hayward CA 64545, 510-293-0580, www.malcomtech.com Metronelec, 54, Rou te de Sartrouville - Le Montreal 78232 Le PECO Cedex, France (USA Distributor: Solderability Testing and Solutions Inc., 18 Wildrose Dr., Edgewood, KY 41017, (859) 331-0598 www.wettingbalance.com Rhesca Tarutin E.1.3 Steam Conditioning Equipment H&H Engineering, Inc., 3612 Wood Duck Circle, Stockton, CA 95206 Metronelec, 54, Route de Sartrouville - Le Montreal 78232 Le PECO Cedex, France (USA Distributor: Solderability Testing and Solutions Inc., 18 Wildrose Dr., Edgewood, KY 41017, (859) 331-0598 www.wettingbalance.com Robotic Process Systems, 23301 E. Mission Ave., Liberty Lake, WA 99019, (509)891-1680 Zentek Scientific Systems, 3520 Yale Way, Fremont, CA 94538, (510)651-1581 -----Original Message----- From: David D. Hillman <[log in to unmask]> To: [log in to unmask] Sent: Fri, 24 Apr 2009 12:11 am Subject: Re: [TN] IPC/EIA-J-STD 002 Steam Ageing Hi Amol! Yes, the more appropriate term is "steam conditioning". Look in he JSTD-002 appendices, there is a listing of the equipment producers Appendix E I think). Dave "Kane, Amol (349)" <[log in to unmask]> ent by: TechNet <[log in to unmask]> 4/23/2009 10:45 AM lease respond to echNet E-Mail Forum <[log in to unmask]>; Please respond to Kane, Amol (349)" <[log in to unmask]> o [log in to unmask] c Subject e: [TN] IPC/EIA-J-STD 002 Steam Ageing hanks Denny. Specifically, I was looking for the names of equipment anufacturers in the US who manufacture Steam Ageing chambers and the olderability testing equipment (dip and look) Thanks, mol From: [log in to unmask] [mailto:ddfritz@a ol.com] ent: Thursday, April 23, 2009 11:03 AM o: [log in to unmask]; Kane, Amol (349) ubject: Re: [TN] IPC/EIA-J-STD 002 Steam Ageing Amol, You are going to get it from Dave Hillman, chairman of IPC 002!!! He ikes to refer to it as "steam conditioning" or "steam stressing". People ry to equate performanc in steam stressing to the aging of the component n storage. Storage in Singapore is far different from storage in innepeg. Is there some part of this paragraph on equipment that is a problem? .3.1 Steam Conditioning Apparatus The steam conditioning chamber shall be onstructed of non-corrodible materials such as orosilicate glass, quartz glass, stainless steel or PTFE. The specimen older shall be non-reactive to prevent galvanic corrosion. The ontainer should be insulated. The steam temperature at the conditioning evel shall be maintained per the requirements of Table 3-2. able 3-2 Steam Temperature Requirements ltitude Average Local oiling Point °C team Temperature imits °C -305 m 100 93 ± 3 05-610 m 99 92 ± 3 10-914 m 98 91 ± 3 14-1219 m 97 90 ± 3 219-1524 m 96 89 ± 3 524-1829 m 95 88 ± 3 safe means to prevent excessive pressure and a means of maintaining dequate water level shall be provided. Neither shall cause he vapor to cool below the specified temperature. Condensate shall drip reely back to the water. Care should be taken to minimize ontact between the condensate and the specimens. Fin ally, do you have comment on either dip-and-look or w etting balance to easure solderability? Denny Fritz acDermid, Inc ----Original Message----- rom: Kane, Amol (349) <[log in to unmask]> o: [log in to unmask] ent: Thu, 23 Apr 2009 9:37 am ubject: [TN] IPC/EIA-J-STD 002 Steam Ageing Dear Technetters, How are people in the industry complying with the category 3, test method , B or C of this requirement for high reliability applications? the 002 tandard calls out for steam ageing and then solderability testing for components. hat equipment is being used for steam ageing and solderability testing? I ould appreciate any direction on this matter (on the forum or offline if omebody so desires) Thanks, Amol WARNING: Export Control This document may contain technical data within the definition of the International Traffic in Arms Regulations (ITAR), and subject to the xport Control Laws of the U.S. Government. Transfer of such data by any means o a foreign person, whether in the United States or abroad, without proper xport authorization or other approval from the U.S. Department of State is prohibited. CONFIDENTIALITY NOTICE: This e-mail, and any attachments, is for the sole use of the intend ed recipient(s) and may contain information that is confidential and protected from disclosure under the law. Any unauthorized review, use, disclosure, or distribution is prohibited. If you are not the intended recipient, please contact the sender by reply e-mail, and delete/destroy all copies of the original message and attachments. Thank you. ------------------------------ --------------------- Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask]<mailto:[log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]<mailto:[log in to unmask]>: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]<mailto:[log in to unmask]>: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 or additional information, or contact Keach Sasamori at [log in to unmask]< ailto:[log in to unmask]> or 847-615-7100 ext.2815 ----------------------------------------------------- ________________________________ reen cleaning products -- do they work as well? Find out now!< ttp://home.aol.com/new_in_home/photogallerytall/_a/spring-cleaning-products-put-to-the-test/20090407180609990001?ncid=emlweushome00000001 WARNING: Export Control his document may contain technical data within the definition of the nternational Traffic in Arms Regulations (ITAR), and subject to the xport ontrol Laws of the U.S. Government. Transfer of such data by any means o a oreign person, whether in the United States or abroad, without proper xport uthorization or other approval from the U.S. Department of State is rohibited. ONFIDENTIALITY NOTICE: his e-mail, and any attachments, is for the sole use of the intended ecipient(s) and may contain information that is confidential and rotected from disclosure under the law. Any unauthorized review, use, isclosure, or distribution is prohibited. If you are not the intended ecipient, please contact the sender by reply e-mail, and delete/destroy ll copies of the original message and attachments. hank you. --------------------------------------------------- echnet Mail List provided as a service by IPC using LISTSERV 15.0 o unsubscribe, send a message to [log in to unmask] with following text in he BODY (NOT the subject field): SIGNOFF Technet o temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) o receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest earch the archives of previous posts at: http://listserv.ipc.org/archives lease visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for dditional information, or contact Keach Sasamori at [log in to unmask] or 47-615-7100 ext.2815 ---------------------------------------------------- --------------------------------------------------- Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815 -----------------------------------------------------