我们用过一段时间,但是在2个月前我们就取消使用这个东西了
很多有经验的朋友告诉我有以下一些情况都可能造成这种不良
1、锡渣被泵带入锡槽打出导致
我们已经两小时清理一次,而且波峰我们一直设置在1200左右(设备最高1400),所以如果这个是根本原因,那到底如何解决啊?
2、锡渣清理不及时
我们有波峰焊作业指导书,而且也确实有进行及时地清理,两小时一次。
3、锡炉温度设置过高
锡炉温度我们曾经调节到245摄氏度过,但是这种短路不良依然频繁发生
4、助焊剂没有挥发完全或者有杂质附着导致
我们使用的是Interflux的无VOC的有机酸助焊剂,应该不会导致这种问题啊
5、锡炉里的锡的杂质成分超标
我们08年11月底对锡成分让第三方做过分析,具体如下,跟标准相比较,好像没有什么元素超标阿


另该不良在PAD稍密集的地方均有可能产生,很离散。

以上这些情况我逐一检查后还是没有找到根据解决办法啊,很迷茫阿  Wisdom,你们也发生过,那证明现在应该没有了对吗?那你们是怎么解决这个问题的呢?
请专家们指教阿,谢谢了......

Zejun Yang |  ME| APC-MGE Critical Power and Cooling Services Division, Schneider Electric.
No. 1678 Jixian Road, Tongan District, Xiamen, China 361100  *: Zejun [log in to unmask]
(Tel) +86 592 757 2775 | (Mobile) +86 15980782161| (Fax) +86 592 757 2899


Wisdom Lu <[log in to unmask]>
Sent by: TGAsia <[log in to unmask]>

21/01/2009 09:24

Please respond to
Asia Committe Task Group Forum <[log in to unmask]>; Please respond to
[log in to unmask]

To
[log in to unmask]
cc
Subject
Re: [TGAsia] dross short





我们也发生过同样的问题.请问一下你们是否用还原锡,还原的锡带杂质是擦拭不掉的.
 
Best Regards!
 
Wisdom



From: TGAsia [mailto:[log in to unmask]] On Behalf Of Tan Geok Ang
Sent:
Wednesday, January 21, 2009 9:09 AM
To:
[log in to unmask]
Subject:
Re: [TGAsia] dross short

 
Perform an overhaul in you wave soldering machine as there is lots of dross within your solder-pot/pump. You wave height (pump height setting) might also pump dross within the solder-pot.
 



From: TGAsia [mailto:[log in to unmask]] On Behalf Of Yang Zejun
Sent:
Wednesday, 21 January 2009 9:02 AM
To:
[log in to unmask]
Subject:
[TGAsia] dross short

 

不好意思,我可能没有描述清楚,不良图片和具体的制程参数如下,目前这种不良在我们这里高达
5%左右,真的很头疼阿,希望专家们能帮帮忙,谢谢了。
                                                                 

制程参数:

PCB: CEM-1                                  
预热:92摄氏度(实测)
锡条:云南锡业
SnPb6337                        锡炉温度:254摄氏度(实测)
助焊剂:
Interflux 精英IF2008                  链条速度:1.2左右
锡炉里的锡渣我们
2小时清理一次,锡的量严格控制在波峰未打开时离炉岗10mm以内。

图片中的短路部分不易发现,导致连锡部分在显微镜下观察表面有一层薄薄的像灰一样的东西包裹,但是里面的东西必须用电烙铁才可以带开,这种不良有时候在
FR4PCBA上也会发生
只要是
PAD稍密集的地方就容易出现,很苦恼啊....
           
 



Zejun Yang |  ME| APC-MGE Critical Power and Cooling Services Division, Schneider Electric.

No. 1678 Jixian Road, Tongan District, Xiamen, China 361100  *: Zejun [log in to unmask]

(Tel) +86 592 757 2775 | (Mobile) +86 15980782161| (Fax) +86 592 757 2899

James Liu <[log in to unmask]>

20/01/2009 23:04


To
Asia Committe Task Group Forum <[log in to unmask]>, "[log in to unmask]" <[log in to unmask]>
cc
 
Subject
答复: [TGAsia] 答复: [TGAsia] 关于检验光的要求

 


   





我不明白你的问题。可否有照片?锡丝怎么会短路?


Best Regards,

James Liu 刘春光
Director, Technology & Standardization 技术与标准总监
IPC China
上海市长宁区延安西路1088号2303室
Suite 2303,#1088 West Yan'an Rd., Changning, Shanghai 200052 PRC
Tel:   +86 21 5497 3435
Fax:  +86 21 5497 3437
MP:   +86 136 0133 3491
[log in to unmask]<mailto:[log in to unmask]>
www.ipc.org.cn<http://www.ipc.org.cn>
________________________________
发件人: TGAsia [[log in to unmask]] 代表 Yang Zejun [[log in to unmask]]
发送时间: 2009年1月20日 11:37
收件人: [log in to unmask]
主题: Re: [TGAsia] 答复: [TGAsia] 关于检验光的要求 !


大家好,我想请问一下锡丝短路怎么处理啊?很细很细的那种。

Zejun Yang |  ME| APC-MGE Critical Power and Cooling Services Division, Schneider Electric.
No. 1678 Jixian Road, Tongan District, Xiamen, China 361100  *: Zejun [log in to unmask]
(Tel) +86 592 757 2775 | (Mobile) +86 15980782161| (Fax) +86 592 757 2899


Mike Ning <[log in to unmask]>
Sent by: TGAsia <[log in to unmask]>

20/01/2009 11:28
Please respond to
Asia Committe Task Group Forum <[log in to unmask]>; Please respond to
Mike Ning <[log in to unmask]>




To
      [log in to unmask]
cc

Subject
      [TGAsia] 答复: [TGAsia] 关于检验光的要求!







IPC-610D 和IPC-620A中前言部分有要求:
1.16 Visual Inspection
1.16.1 Lighting Illumination at the surface of workstations should be 1000 lm/m2 minimum. 1,000 lm/m 2 at the work surface is the accepted practice for the minimum level of illumination in which operators and inspectors should be expected to perform their tasks. 1,000 lm/m 2 is approximately equivalent to 100 foot-candles measured using a photographic light meter.
1.16.2 Magnification Aids and Lighting When required, magnification power for assembly inspection shall1 be at least the minimum inspection power specified in Table 1-2. Other magnification powers within the inspection range may be used. The magnification power requirement is based on the gauge of the wire being inspected. For assemblies with mixed wire sizes, the greater magnification may be used for the entire assembly. If the presence of a defect cannot be determined at the inspection power, the item is acceptable. The referee magnification power is intended for use only after a defect has been determined but is not completely identifiable at the inspection power.

The tolerance for magnification aids is ± 15% of the selected magnification power. Magnification aids should be maintained and calibrated as appropriate (see IPC-OI-645). Supplemental lighting may be necessary to assist in visual assessment.

Table 1-2 Magnification Aids1

Wire Size AWG
Diameter mm [inch]

Magnification Power

Inspection
Range

Maximum Referee

larger than 14 AWG
2 mm [0.081 in]

N/A

1.75X

14 to 22 AWG
1.6 - 0.63 mm [0.064 to 0.025 in]

1.5X - 3X

4X

smaller than 22 AWG
<0.63mm [<0.025]

3 – 7.5X

10X



Note 1: Referee magnification power is to be used only to verify a product rejected at the inspection magnification. For assemblies with mixed wire size, the greater magnification may be (but is not required to be) used for the entire assembly.

Best Regards,

Mike Ning

Sanbor Xiamen Manufacturing, Inc.
3/4F, 47 South Haijingnan 2nd Rd, Haicang , Xiamen AEPZ, China.
Post: 361026
Tel :+86-592-5099000 ext 8305
Fax:+86-592-5099343
www.sanbor.com



________________________________
发件人: TGAsia [mailto:[log in to unmask]] 代表 WTSZ-Anny Zhou
发送时间: 2009年1月20日 11:08
收件人: [log in to unmask]
主题: [TGAsia] 关于检验光的要求!

[cid:_2_05639D0405639AB00013ED0A48257544]

Dear all.

大家好,我想问一下IPC有没有对检验工位的灯光和环境有明确规定的?

∽∽∽∽∽∽∽∽∽∽∽∽∽∽∽∽∽∽

Best Regards    ^⊥^

anny zhou

Welco(Suzhou)

* Phone: 86-512-62838860 ext. 8116

* Fax: 86-512-62830728

* E-Mail: [log in to unmask]<mailto:[log in to unmask]>

∽∽∽∽∽∽∽∽∽∽∽∽∽∽∽∽∽∽


________________________________
Important Notice: This message is intended only for use by the addressee(s) and may contain information that is privileged and confidential. If you are not the intended recipient(s), you are hereby notified that any form of disclosure, distribution, copying or use of this communication is strictly prohibited and may be unlawful. If you have received this communication in error, please notify us immediately by reply and delete the email and destroy any copies of it. This email is for information purposes only and is not intended to nor will it create any binding legal relations. Wong's International (Holdings) Limited.<http://www.wongswih.com/>