个人认为,这种传送带可以作为自动化的取放器来看待,那么在ESD S20.20表中,对于它的要求是ESD DSP 10.1。第一,设备一定要接地。第二,用场电压表测量传送带的表面,如果表面静电电压小于2000V,那么就没什么距离问题,如果大于2000V,应该保持12英寸的距离。不知道这样理解是否正确。

 

From: TGAsia [mailto:[log in to unmask]] On Behalf Of Wentao Hu
Sent: Friday, June 08, 2007 2:06 PM
To: [log in to unmask]
Subject: [TGA] 双层皮带拉的间距问题

 

各位同仁,

 

请问有谁可以帮忙解答一个问题:

有没有相关行业标准规定,在设置双层皮带拉时,两层皮带面的高度差要求最少是多少?(主要是考虑ESD问题)。

附图如下:

  

 

Legal Disclaimer: The information contained in this message may be privileged and confidential. It is intended to be read only by the individual or entity to whom it is addressed or by their designee. If the reader of this message is not the intended recipient, you are on notice that any distribution of this message, in any form, is strictly prohibited. If you have received this message in error, please immediately notify the sender and delete or destroy any copy of this message