From: Leadfree [mailto:[log in to unmask]] On Behalf Of Ron Pickard
Sent: Friday, January 19, 2007 3:42 PM
To: [log in to unmask]
Subject: [LF] China RoHS EFUP calculation?

Is there anyone on this list able to figure out how to calculate the
Technical EFUP (Technical Life Method) from the recently available China
RoHS EFUP draft standard? What units is the term "Technical Life" in the
equation (I'm assuming years)? Anyway, leaving all terms unitless I
calculate a ridiculously small number using those equations. For
example, using TL=10 & ADWT=0.75 (18hours/day) calculates to 0.037, or
using TL-10 & ADWT=18 calculates an even smaller number.

I'm wondering, is there something wrong with those equations correct or
am I missing something? These equations appear to leave a lot to
interpretation.

All replies/comments are welcome.

Best regards,
 
Ron Pickard
[log in to unmask]

----------------------------------------------------------------------------
---Leadfee Mail List provided as a service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Leadfree
To temporarily stop/(start) delivery of Leadree for vacation breaks send:
SET Leadfree NOMAIL/(MAIL)
Search previous postings at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
----------------------------------------------------------------------------
---

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------