We do something like this on occasion, but we run the wave machine in manual mode - turn the conveyor off when the board is right over the wave, and then turn the wave on. Count to 5 and gently pull up... have an assistant turn the wave off. We have also replaced connectors this way, on occasion. Very handy for very large connectors, but otherwise not recommended... and keep in mind that there are lots of very hot things in there where you usually don't stick your hand. regards, Graham Collins Process Engineer, Northrop Grumman Canada Corporation Halifax (902) 873-2000 ext 6215 >>> [log in to unmask] 11/05/04 12:04PM >>> Try this method using a scrap board first to get a feeling of the fine details. Mask board area around the connector with hi temp tape or other material. Preheat board in an oven. Place board on a solder wave fixture. Have one person slide the fixture over the wave till connector is right over the solder and another pull up gently and easy the connector after about 8 seconds. Regards, Ramon -----Original Message----- From: TechNet [mailto:[log in to unmask]]On Behalf Of Poh Kong Hui Sent: Friday, November 05, 2004 8:57 AM To: [log in to unmask] Subject: Re: [TN] Removal of Connector Hi Technetters, I am facing an issue with a board of 10 layers and 2mm thick, gold plated. I need to remove a 72 pin through hole connector. However, I am not able to remove the connector using solder iron & solder sucker. I understand if I am to use solder pot, I should be able to remove it. But I do not have a mini-solder pot. I am wandered if there is other way to take out the connector. Can someone help to advise me other methods to remove the connector. Thanks. Poh --------------------------------------------------- Technet Mail List provided as a service by IPC using LISTSERV 1.8e To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815 ----------------------------------------------------- --------------------------------------------------- Technet Mail List provided as a service by IPC using LISTSERV 1.8e To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815 ----------------------------------------------------- --------------------------------------------------- Technet Mail List provided as a service by IPC using LISTSERV 1.8e To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815 -----------------------------------------------------