Hi "estellrecht,"
You mare suffering from inner-layer separation. ILS comes in 3 flavors, and 
unfortunately they typicallly involve the whole lot or may be even systemic to 
the design. Also unfortunately, there is no non-destructive screening 
methodology--it would also not be very useful, since you would be screening out 
essentially everything.
The failure mode tells you where your problem lies, and how to fix it in 
future product.

Regards,
Werner Engelmaier
Engelmaier Associates, L.C.
Electronic Packaging, Interconnection and Reliability Consulting
7 Jasmine Run
Ormond Beach, FL  32174  USA
Phone: 386-437-8747, Fax: 386-437-8737
E-mail: [log in to unmask], Website: www.engelmaier.com 

---------------------------------------------------