Hello,

 

I have seen an increase in problems with electrical testing and it has been traced to BGAs.

I have a few questions regarding BGA and processes.  I am trying to understand if the problem is process related (SMT) or do I have a vendor issue with BGA.

 

  1. Open contact between the ball and the package.  This is verified by pressing onto the package while testing.  Pressing the package down causes the board to pass.
  2. Visual inspection reveals the ball not touching the PCBA. (You may have a ball in  the middle not touching and the balls on each side are)
    1. Question:  With on ball in the middle not touching and the balls next to it are, is this indicative to SMT process issues or BGA package issues?
    2. Question:  What type of inspection can be performed on BGAs prior to SMT to capture Bad BGA?

                                                               i.      Is the industry standard 100% or Sample inspection for out going quality inspection?

    1. Question: Is it easy to identify a BGA that has been re-balled and if so how?
    2. Is it customary for distributors to re-ball BGA
    3. What other test or inspections can be performed to capture BGA with open contacts?
    4. As indicated above, pressing down the package causes the board to pass, how do I detect micro cracking of the solder joint? And what would cause micro cracking?

 

I am lost at this point and am looking for additional suggestions and assistance in educating me on BGA.

 

David Harman

 

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------