Thanks, Rudy,
Gaby
----- Original Message -----
From: [log in to unmask] href="mailto:[log in to unmask]">Rudy Sedlak
To: [log in to unmask] href="mailto:[log in to unmask]">[log in to unmask]
Sent: Saturday, July 05, 2003 1:37 AM
Subject: Re: [TN] Nickel separation

Gabriela:

We saw something which I suspect is related to this often in the old days of fusing Tin/Lead on the PCB...and I would bet the cause of the problem is what is causing your problem.

In the old days, they would immerse the board into a fluoboric acid solution then into the (fluoboric based) Tin/Lead plating solution, and we saw non-adherent Tin/Lead deposits (they were called "dewetting") if the Fluoboric acid pre-dip had enough Copper, and the boards were left long enough.

The Copper in the fluoboric acid pre-dip would react with the Copper on the boards to create an insoluble (and invisible) Cuprous salt deposit on the Copper.   You could plate over it, but the plating was non-adherent.

Suspect the same may be happening to your board... The fabricator is parking the board in an acid pre-plating dip, and not changing the acid dip often enough, and picking up Copper in the acid, which is causing you your problem...

And remember the wise words someone once said, "Free advice is often not worth what you paid for it...:-)"  

Rudy Sedlak
RD Chemical Company
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------