Geoff,
If you are referring to UL ZPMV2 it is the UL classification for PWB fabrications.
It used to be referred to as/in the UL yellow card for PWB Fabricators.
Calling out UL RECOGNIZED COMPONENT ZPMV2 on a drawing means the PWB must be a UL approved construction for the specific Supplier building the PWB.

Hope it helps,
FNK

Frank N Kimmey CID+
Sr. PCB Designer
Powerwave Technologies
EDH 916-941-3159
FAX 916-941-3195


-----Original Message-----
From: Geoff Layhe [mailto:[log in to unmask]]
Sent: Wednesday, June 11, 2003 7:31 AM
To: [log in to unmask]
Subject: [TN] UL Designator.


Does anyone know what UL ZPM PV2  is. I did a quick search on the UL site
but didn't find anything.

Geoff


Private & Confidential:
This e-mail message is confidential and is intended solely for the person or
organisation to whom it is addressed.  If the message is received by anyone
other than the addressee please return the message to the sender by replying
to it and then delete the message from your computer.

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------