Inner layer separation can occur between the electroless copper and the inner layer foil, between the electroless copper and the electrolytic copper and totally within the electroless deposit - that is if the boards were built with electroless copper. Each of these has their own set of causes, which is a very long list.
Assembly operations can cause inner layer separation on good boards, but this is very rare. Excessive temperatures can do this expecially on a pin that has multiple ground and power plane connections and is difficult to remove and replace. However, this is rare. If separation shows up in assemblies there was most likely a weakness there to begin with in the bare board.
Perhaps if you tell us where the separation occurs or send a picture of a micrograph, we can give you all of the possible process steps that might have an effect.
Susan Mansilla
Robisan Lab
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------