Mel Parrish
Director, Training Materials
Resources
Soldering Technology International
102 Tribble Drive
Madison,
AL 35758
256 705 5530
256 705 5538
Fax
[log in to unmask]
www.solderingtech.com
-----Original Message-----Hi All!
From: TechNet [mailto:[log in to unmask]]On Behalf Of Steve Gregory
Sent: Thursday, October 24, 2002 9:07 AM
To: [log in to unmask]
Subject: [TN] Side and Toe Fillets...
I've got a situation here with a SMT socket. It's a SAMTEC CLT-105-02-L-D. The leads are made from stamped pre-plated stock, so the sides and toes of the leads have exposed copper, and of course doesn't wet during reflow.
In J-STD-001B, it used to say under 9.2.6.1 Flat, Ribbon, "L" and Gull Wing Leads:
"Leads not having wettable sides or ends by design (such as leads stamped or sheared from pre-plated stock) are not required to have side or end fillets.
In J-STD-001C it has no mention of that under the same section, in J-STD-001C the section number has changed, it's 9.2.6.8.
So if you have leads that are made from pre-plated stock and have the sides and toes not wet because of the exposed copper, is it now a defect? If it is, how in the heck are you going to get the sides and toes to wet?
Thanks!
-Steve Gregory- --------------------------------------------------- Technet Mail List provided as a free service by IPC using LISTSERV 1.8e To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/html/forum.htm for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315 -----------------------------------------------------