Answers:
1. You compensate by varying the line width
of the trace. You need an impedance calculator to get the values.
2. I'm familiar with designs with the
laminate thickness as low as 3 mils. I'm sure the fabricators on this forum
have a better answer.
David Ricketts
Pertek Engineering
Voice:
949-475-4485
Fax: 949-475-4493
----Original Message-----
From: TechNet
[mailto:[log in to unmask]]On Behalf Of Sefika Ozkal
Sent: Friday,
October 11, 2002 5:35 AM
To: [log in to unmask]
Subject: [TN]
Thickness Problem
Hi,
If we have a PCB with signal layers whose thicknesses
are 6, 8, 10,12 mils, how can compansate the impedance differences? To achieve
the impedance requirements of a design can you offer some
solutions?
What can be the minimum thickness of the laminate
between the VCC and GND planes where the laminate can be FR4
or?
Sefika Ozkal
Electronics
Engineer
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in the BODY
(NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start)
delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or
(MAIL) To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest Search the archives of previous posts at:
http://listserv.ipc.org/archives Please visit IPC web site
http://www.ipc.org/html/forum.htm for additional information, or contact Keach
Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------