Rudy,
Thanks for your reply. Any thoughts on solderability after
multiple heat cycles. Our current involve 2 reflow cycles as well as some
postwave handsoldering. We encounter problems with the handsoldering
operations, particularly when boards have been sitting in storage 4+
months.
Wendy
Worth
Harris
Corporation
585-242-4543
Wendy:
The chemical that is the real "cause",
or engine, of immersion Tin is:
Stannous Chloride (Thiourea
Complex) and this item is not real soluble, (read that as
rinseable). You want thick Tin plate (for shelf life reasons), and in
order to have thick Tin, your fabricator needs a lot of this chemical in
solution, usually held in solution by it being heated. When this stuff
hits cold rinse water, it can set up like a gooey gel, and be difficult to
rinse.
Back in the days when we used to use immersion Tin to cover
dewetting on reflowed boards...this is really the stone age, most readers will
be too young to remember, we used to use hot water first rinse, to assure
getting good rinsing.
I do not recommend HOT rinsing, but I do think
WARM rinsing is not a bad idea.
Rudy Sedlak
RD Chemical
Company
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in the
BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet
NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail
to [log in to unmask]: SET Technet Digest Search the archives of previous posts
at: http://listserv.ipc.org/archives Please visit IPC web site
http://www.ipc.org/html/forum.htm for additional information, or contact Keach
Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------