Rich,
Hmm, sounds to me that there is either a batch related problem or worse yet, a supplier related problem.  Both Nortel and now RIM have used ENIG extensively in products.  Both Nortel and RIM reliability testing has used humidity as a variable without problem.
Bev
-----Original Message-----
From: Rick Fudalewski [mailto:[log in to unmask]]
Sent: June 17, 2002 10:22 AM
To: [log in to unmask]
Subject: Re: [TN] ELni/au

Bev

reason why i was asking about the elni/au - customer had recommended to their OEM customer - but was informed that the immersion gold did not stand up to humidity testing - is there something that went wrong?

Rich F

FCT