A question regarding the "total pad mating area" in the formula below. Does
one take into consideration only the area where the bottom of the lead
contacts the pad, or the entire pad area? And, is the contact area of the
bottom of the lead and the contact area of the top of the pad in contact
with the lead added together to get the total contact area for that lead?
Hope this question makes sense!

Bob


  -----Original Message-----
  From: TechNet [mailto:[log in to unmask]]On Behalf Of Howard Watson
  Sent: Wednesday, March 27, 2002 12:12 PM
  To: [log in to unmask]
  Subject: Re: [TN] Double Sided Reflow Flux and surface tension



  Ed,

  I can't answer your questions regarding the OA flux and BGA's, but I can
help with your other questions:

  "Is there a rule of thumb for the pad surface area / part weight ratio to
  maintain enough surface tension to correctly hold the part?"  Yes, as
stated in previous TechNet threads on the subject, the "rule of thumb"
formula is the weight of the component in grams / Total pad mating area in
square inches.  The resulting value in grams per sq. in. must be less than
30.