Darrel, There is no magic formula to calculate the stackup tolerance. However your Mechanical engineering should be able to run simulation of stacked tolerances to look at the effect on the final dimension. Using standard normal distribution and statistical analysis. It has been done routinely by mechanical engineers. pratap www.rampinc.com --------------------------------------------------------------------------------- Technet Mail List provided as a free service by IPC using LISTSERV 1.8d To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315 ---------------------------------------------------------------------------------