I would agree that form fit and function should govern the acceptance decision. Mike Hill > -----Original Message----- > From: John Perry [SMTP:[log in to unmask]] > Sent: Tuesday, January 23, 2001 4:16 PM > To: [log in to unmask] > Subject: [IPC-600-6012] Nonconforming Condition for Nonmetallic > Burrs? > > Hi All, > > > Got an issue here raised by one of our IPC-A-600F users. The attached > .pdf contains a photograph that shows the board edge of a sample which the > user believes does not pass the criteria established in section 2.1.1.1., > Nonmetallic Burrs. It would appear as though the router had some problems > on the edges and fiberglass fibers are now falling off the edges. > > Does this provide sufficient information in order to obtain a consensus > from this group on the pass/fail issue? > > > Best Regards, > > > > > John Perry > Technical Project Manager > IPC > 2215 Sanders Road > Northbrook, Il 60062 > 1-847-790-5318 (P) > 1-847-509-9798 (F) > [log in to unmask] > << File: Loose f1.pdf >>