The non-conforming part of the lamination also depend on the distance to a conductor and if the fraying will be a form fit or function in high in-use moisture condition. Clarence WKnapp M&P Engineering Litton G/CS Ph 818 715-2478 Fx 818 715-4986 knapp@ littong/cs.com -----Original Message----- From: John Perry [SMTP:[log in to unmask]] Sent: Tuesday, January 23, 2001 1:16 PM To: [log in to unmask] Subject: [IPC-600-6012] Nonconforming Condition for Nonmetallic Burrs? Hi All, Got an issue here raised by one of our IPC-A-600F users. The attached .pdf contains a photograph that shows the board edge of a sample which the user believes does not pass the criteria established in section 2.1.1.1., Nonmetallic Burrs. It would appear as though the router had some problems on the edges and fiberglass fibers are now falling off the edges. Does this provide sufficient information in order to obtain a consensus from this group on the pass/fail issue? Best Regards, John Perry Technical Project Manager IPC 2215 Sanders Road Northbrook, Il 60062 1-847-790-5318 (P) 1-847-509-9798 (F) [log in to unmask] << File: Loose f1.pdf >>