Mike

Here are a few issues that you should investigate in regard to material
compatibility before proceeding.

1.  Will the residue remaining from the no clean flux absorb the solvent from
the candidate conformal coat material?
2.  Will the resulting mixture of coating and no clean residue change the
electrical characteristics of the circuit (i.e. dielectric constant,
impedance)
3.  Will the resulting mixture be prone to moisture absorption in your
application?

If you need further guidance on how to investigate these concerns, please
contact me offline.

Regards,

Pat Kane
Technical Sales Manager
Contamination Studies Laboratories
765-457-8095  office
765-419-2080  cell

##############################################################