Steve, Try Agilent's HP 4284A LCR meter. It can measure down to 0.01nH. That's what my company has been using in one of the manufacturing locations. If you find it an overkill or out of your budget, try the HP 4263B. I never use it but its spec says it measures down to 10nH. Also, don't forget to buy the right test jig to zero out the wiring inductance. Just a reminder. Such low inductance means very low impedance. It poses a challenge to the LCR meter's internal power supply. Some cheap LCR meters end up running into overcurrent protection and produce deviated reading. A meter with higher measuring frequency helps to scale up the impedance for more accurate measurement. KK Chin Artesyn Technologies, Fremont, CA "Stephen R. Gregory" <[log in to unmask]> on 06/19/2000 06:13:50 PM Please respond to "TechNet E-Mail Forum." <[log in to unmask]>; Please respond to [log in to unmask] To: [log in to unmask] cc: (bcc: KK Chin) Subject: [TN] Inductor measuring equipment... Hi ya'll! Does anybody know of any inductance measuring equipment that can measure the inductance down in the 1.0nh range? I can find stuff on the net that go down to 1.0mh range, but nothing that goes down in the nano-henry range...'scuse me if I'm asking a dumb question (I know that is a very small amount of inductance to measure, and I'm not up on that stuff enough to know IF it actually can be measured...I think it can, but what does it take?) but I thought I'd ask anyway. I need it to verify what are supposed to be some 1.8nh SMT chip inductors... -Steve Gregory- ############################################################## TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c ############################################################## To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body: To subscribe: SUBSCRIBE TECHNET <your full name> To unsubscribe: SIGNOFF TECHNET ############################################################## Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional information. If you need assistance - contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315 ############################################################## ############################################################## TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c ############################################################## To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body: To subscribe: SUBSCRIBE TECHNET <your full name> To unsubscribe: SIGNOFF TECHNET ############################################################## Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional information. If you need assistance - contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315 ##############################################################