Susan

reason for the elctroless doing that is 1) - at times when u do a section and
look closely - there is an inclusion in the deposit - whether from the bath
or from the resin - matters not - 2 - if ur getting a spongy - amorphous
copper deposit - it's really out of balance - would look into the stabilizer
package when that is happening. but to tell uthe truth - haven't seen many
spongy deposits - unless you are referring to blisters in the hole - then
would look at the reducer.

regards

Richard Fudalewski