It all depends. For prototype during development, it can be any number. In production,
if the number is more than 1-2 percent of circuits ( read as traces) on the board, you
have a design/manufacturing problem. Typically an engineering change (EC) is done on
the design and board is refabed. More repair wires  means higher probability of failure
in the field.

[log in to unmask] wrote:

> Hi All
> Is there a document that addresses the number of jumper wires that  can be
> used
> on an assembly that are not a part of the original design.  You know the kind
> that
> are put on to solve "open" problems.  Geeeesh!
>
> Susan Mansilla
>
> ##############################################################
> TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
> ##############################################################
> To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
> the body:
> To subscribe:   SUBSCRIBE TECHNET <your full name>
> To unsubscribe:   SIGNOFF TECHNET
> ##############################################################
> Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
> information.
> If you need assistance - contact Gayatri Sardeshpande at [log in to unmask] or
> 847-509-9700 ext.5365
> ##############################################################

--
____________________________________
Regards,
Pratap Singh

Tel./Fax: 512-255-6820,
e-mail: [log in to unmask] or [log in to unmask]

##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe:   SUBSCRIBE TECHNET <your full name>
To unsubscribe:   SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Gayatri Sardeshpande at [log in to unmask] or
847-509-9700 ext.5365
##############################################################

ATOM RSS1 RSS2