Hi Bernhard,
At Bell Laboratories we found that 1812's were not suitable in
telecommunications outside plant environment from a solder joint reliability
perspective (not considering 1812's with thicker solder joints due to
gluing). CC's are susceptible to component cracking depending on the size of
the solde fillet--the larger the fillet, the more stress on the CC's. Also,
too rapid cooling from reflow can cause thermal shock stresses that are too
high.