Subject: | |
From: | |
Reply To: | DesignerCouncil E-Mail Forum. |
Date: | Sat, 18 Sep 1999 12:25:48 -0400 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Okay...thanks for letting me know soon.
-----Original Message-----
From: Chris Robertson [mailto:[log in to unmask]]
Sent: Friday, September 17, 1999 3:02 PM
To: [log in to unmask]
Subject: [DC] I hope
Regarding thermals, I was trained to make the ID of the thermal the
same as an internal pad/land + 10Mil + 10%
The OD and the web at 25% of the ID (pad/land)
Researching this several years ago I found that this was above and beyond
most specs.
I'm now looking at the IPC spec and it dosen't make a hell of a lot of
sense.
I'm sure there are others out there that don't quite understand.
Could someone clarify?
If there are any bugs, suggestions, etc. there is a "format"
that would help tech support identify our problems.
Software; Accel PCB
Version; V15
Date;
Subject;
Description;
Reason; (If necessary)
I'm assured that this will help Tech support process out emails.
Chris Robertson
PCB Designer
Lockheed - Martin Services, Inc.
[log in to unmask]
Ph/Fax (256) 722-2626
ICQ# 13541566
This has been cross posted. Please ignore irrelevant information
|
|
|