TECHNET Archives

August 1999

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Blomberg, Rainer (FL51)" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Fri, 27 Aug 1999 15:55:42 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (65 lines)
Ron,
Reading from Mil-G-45204C, (cancelled 7 April 1998) this is
electrodeposited, 99.0 percent gold, minimum, knoop hardness 130-200.  A
nickel underplate of greater than 10 microinches would be required per para.
6.3 depending on the basis material. Para. 3.4 requires the strike and
underplating to be .001 inch minus the specified thickness of the gold
plating if the basis metal is low alloy steel or other non-copper base
metal.
You should consider using AMS 2422 and/or ASTM B488 as a replacement
specification.

R. G. Blomberg
Honeywell
Staff Production Engineer
(727) 539-5534


-----Original Message-----
From: TPE Engineering TechNet [mailto:[log in to unmask]]
Sent: Friday, August 27, 1999 1:50 PM
To: [log in to unmask]
Subject: [TN] Mil-G-45204


I have a drawing that requires keypads to be plated with
gold. This drawing references MIL-G-45204, type 2, grade C
class 00. What type of gold is this? Electrolytic, immersion
or electroless. How much nickel is required to be plated
under this gold? Any help I can get on this would be
appreciated.
Thanks,
Ron Hayashi
Toppan Electronics
1-858-695-2222, ext. 243
[log in to unmask]

##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following
text in
the body:
To subscribe:   SUBSCRIBE TECHNET <your full name>
To unsubscribe:   SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Gayatri Sardeshpande at [log in to unmask] or
847-509-9700 ext.5365
##############################################################

##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe:   SUBSCRIBE TECHNET <your full name>
To unsubscribe:   SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Gayatri Sardeshpande at [log in to unmask] or
847-509-9700 ext.5365
##############################################################

ATOM RSS1 RSS2