TECHNET Archives

August 1999

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Bill Davis <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Thu, 5 Aug 1999 09:36:24 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (40 lines)
Try hydrogen embrittlement as a root cause. What's the oxygen content of
your copper?


Bill Davis, Ph.D.

Principal & Vice President/IP Managers

[log in to unmask] <mailto:[log in to unmask]>



-----Original Message-----
From: Joan M.Slade [mailto:[log in to unmask]]
Sent: Saturday, July 31, 1999 7:13 AM
To: [log in to unmask]
Subject: [TN] copper cracking



I have a question in regards to copper plating cracking on Teflon(tm)
materials.
The problem is only seen after ni / au plating. If the boards are flexed,
the underlying copper cracks. What would cause this ?
We are baking the boards and removing humidity issues.

##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe:   SUBSCRIBE TECHNET <your full name>
To unsubscribe:   SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Gayatri Sardeshpande at [log in to unmask] or
847-509-9700 ext.5365
##############################################################