> > Hi Technetters:
> >
> > Our Production Manager has issued a work
> > instruction for signature approvals. The solder side pictorial shows an
> > insulated jumper wire being routed between leads of several ICs. I asked
> > why he routed this way. The answer was that it is the shortest path. I
> > chose a different path that is a bit longer yet does not cross through
> > any pins. The operator would need to dab glue on an extra corner. We
> > looked through IPC 610C for rules. The acceptable pictures show jumpers
> > going through pins. The jumpers in 610 do not follow x-y routings like I
> > was taught.
> >
> > |
> > o o o o o o o o |
> > o o o o o o o o |
> > o o o o o o o o |
> > o o o o o o o o |
> > o o o o o o o o |
> > o o o o o o o o | jumper
> > o ____o__o_____o__o______o__o_____o___|
> > o o o o o o o o
> > o o o o o o o o
> > o o o o o o o o
> > o o o o o o o o
> > o o o o o o o o
> > o o o o o o o o
> > o o o o o o o o
> >
> > Please advise and explain why we can or can't route as the production
> > manager wants.
> >
> >
> >
> >
> > Thanks
> >
> > Ellen Berkman
> > QA Manager, Excalibur Systems
##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe: SUBSCRIBE TECHNET <your full name>
To unsubscribe: SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Gayatri Sardeshpande at [log in to unmask] or
847-509-9700 ext.5365
##############################################################