Subject: | |
From: | |
Reply To: | TechNet E-Mail Forum. |
Date: | Tue, 31 Aug 1999 14:04:08 +0100 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Marvin,
There are a LOT of factors to look at when you are trying to obtain and
maintain good plating distribution. Here's a few quick ones to be going
on with. I'm sure there'll be more.
Solution agitation, espescially if the filtration uses the same pump.
Air agitation
Board movement
Anode:cathode area ratio
Anode;cathode distance
Acid:copper ratio
Anode dimensions relative to the board
Connections
Cleanliness of dry film developer solution
Conductivity of direct metalisation if used.
Pulse plating
"Baffle plates" between anode & cathode
Precleaning chemistry
I guess none of the above will give you a big improvement on their own,
but by improving and controlling each of them you should see a good
overall improvement.
Depending on your particular set-up I would go for solution agitation
first.
Hope this helps
Geoff Layhe
www.lamar-uk.co.uk
> ----------
> From: marvin v. picardal[SMTP:[log in to unmask]]
> Reply To: TechNet E-Mail Forum.;marvin v. picardal
> Sent: 31 August 1999 22:24
> To: [log in to unmask]
> Subject: [TN] how to improve plating distribution
>
> TECHnet'rs,
> Greetings!!! PCB Geniuses
>
> I want to gather suggestions regarding items to be considered to
> maintain even distribution for copper plating. So far I have already
> evaluated the effect of board spacing, organic chemical dosage
> control, tank design modification. But the result shows only few
> developments.
>
> Other related principles such as that of mass transfer would be of
> great help.
>
> thank you.
>
>
> Marvin
> Chemical Engineer
> PWB
>
> ##############################################################
> TechNet Mail List provided as a free service by IPC using LISTSERV
> 1.8c
> ##############################################################
> To subscribe/unsubscribe, send a message to [log in to unmask] with
> following text in
> the body:
> To subscribe: SUBSCRIBE TECHNET <your full name>
> To unsubscribe: SIGNOFF TECHNET
> ##############################################################
> Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
> additional
> information.
> If you need assistance - contact Gayatri Sardeshpande at
> [log in to unmask] or
> 847-509-9700 ext.5365
> ##############################################################
>
##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe: SUBSCRIBE TECHNET <your full name>
To unsubscribe: SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Gayatri Sardeshpande at [log in to unmask] or
847-509-9700 ext.5365
##############################################################
|
|
|