We have a very serious dewetting problem with at least one supplier. We have
seen as much as 80% with the HASL down to 10 microinches. The area of
dewetting can not be reflowed, we have tried. problem is from copper/tin
intermettalics, poor cleaning after applying solder mask, contamination,
etc. get a good FA lab like NEXTEK and have them run on a X-Ray floroscope.

##############################################################