Yes

Check the water quality rinse after pumice scrubbing.  The water rinse may
use a soap that isn't being rinsed well or that the product is passing to
quickly through the rinses 10-15 ft/min.  Check the temperature of the water
also colder water dosen't clean as well as hotter.  (125 to 145 F)

Terry Munson
[log in to unmask]
CSL Inc.
765-457-8095

################################################################