Michael,

I use the 3-parameter Weibull plot in an MS Excel program to simulate PTV
reliability in PWBs under various thermal cycling scenarios.  It predicts
mean fatigue life of plated-through-vias and is largely based on IPC-TR-579
[Engelmaier, et.al.].  I have experimented with various shape factors but
usually use alpha=3, which skews the probability curve just left of normal.
 Given about a dozen input parameters of the PWB, it generates two graphs:
(1) Weibull cumulative distribution and (2) Weibull failure probability
density.
If I can be of further assistance, please reply directly via e-mail.

Joe Felts

-----Original Message-----
From:   Michael Becker [SMTP:[log in to unmask]]
Sent:   Tuesday, April 13, 1999 7:52 AM
To:     [log in to unmask]
Subject:        [TN] Anatech box/3 parameter Weibull

1)Does anyone have a contact at Anatech(analysis Technology) or have an
Anatech Box for rent or lease available for a short period of time?(<2
months)

2) Does anyone have experience with a 3 parameter Weibull plot?


Please email me at [log in to unmask]

thanks,
Michael

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following
text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section
for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or
847-509-9700 ext.312
################################################################

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################


ATOM RSS1 RSS2