Good morning, technetters,

We aer using Alpha 600SMD for detecting the ionic contamination of bare
PCB.  All boards are D.I. rinse and dried prior for the testing.  The
reading come out is about 10ug NaCl/sq.in.  However, when the boards sent
to baking at 110 C for four hours and the boards are tested again, the
reading drop to 3ug NaCl/sq. in.   We do not suspect inadequate baking at
the first time.  We bake the boards at 150 C for 65 mins.  The solder mask
is photoimagable solder mask.

This is not a single case.  Everytime when the contamination is failed,
then bake the boards again, the result turn to positive.  However, if we
prolong the baking time at the first baking, it does have this result
apparently.

Do you have this experience?

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################


ATOM RSS1 RSS2