TECHNET Archives

March 1999

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Phil Hersey <[log in to unmask]>
Reply To:
Phil Hersey <[log in to unmask]>
Date:
Wed, 24 Mar 1999 07:59:38 -0800
Content-Type:
text/plain
Parts/Attachments:
text/plain (23 lines)
I am chronically failing RGA (residual gas analysis) despite several hours
of vacuum bake.  I vaguely remember from my sputtering days that vacuum
alone is not the best way to remove moisture - vacuum dep. machines use a
"nitrogen trap".

Does anyone know of better ways than vac. bake to remove H2O from PCB
assemblies which will later be hermetically sealed and tested for RGA?

Resp.
Phil Hersey, Carson City Nevada USA

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################