"Norton, Bill" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Mon, 22 Mar 1999 10:29:41 -0600
Content-Type:
text/plain
Parts/Attachments:
text/plain (97 lines)
Dave & Mark

Try MIL-P-55110E Table IX Equivalence factors.


> -----Original Message-----
> From: Mark Austin [SMTP:[log in to unmask]]
> Sent: Monday, March 22, 1999 10:05 AM
> To:   [log in to unmask]
> Subject:      Re: [TN] Circuit Card  Cleanliness
>
> Dave
>
> We are using an Ionograph Contaminometer (ZI 100) and the MIL spec limit
> for
> this type of tester is 37ug per square inch when used in the un-timed
> setting.
>
> I cant recall the number of the MIL spec but someone else out-there may
> know.
>
>
>
> ===== Original Message from [log in to unmask] (TechNet E-Mail Forum.) at
> 22/03/99 13:01
> >IPC,
> >
> >
> >I am using IPC - CH - 65 Guide for cleaning PCB's.
> >
> >I am using an Ionograph Contaminometer to check contamination levels
> >on populated boards.
> >Is there a standard max level for the surface area of a board, such
> >as 1.5ug / SQ CM.
> >
> >The Ionograph does not quote a standard max level.
> >I will be greateful for any help you can give.
> >
> >Best Regards,
> >
> >Dave,   Quality  Control  Technician.
> >
> >################################################################
> >TechNet E-Mail Forum provided as a free service by IPC using LISTSERV
> 1.8c
> >################################################################
> >To subscribe/unsubscribe, send a message to [log in to unmask] with
> following text in the body:
> >To subscribe:   SUBSCRIBE TechNet <your full name>
> >To unsubscribe:   SIGNOFF TechNet
> >################################################################
> >Please visit IPC's web site (http://www.ipc.org) "On-Line Services"
> section for additional
> information.
> >For technical support contact Hugo Scaramuzza at [log in to unmask] or
> 847-509-9700 ext.312
> >################################################################
>
>
> Mark Austin (Process Engineer)
> ACW Technology Limited
> Hylton Road
> Petersfield
> GU32 3XX
> ENGLAND
>
> TEL - +44 (0) 1730 300000
> FAX - +44 (0) 1730 266045
>
> Email - [log in to unmask]
>
> ################################################################
> TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
> ################################################################
> To subscribe/unsubscribe, send a message to [log in to unmask] with
> following text in the body:
> To subscribe:   SUBSCRIBE TechNet <your full name>
> To unsubscribe:   SIGNOFF TechNet
> ################################################################
> Please visit IPC's web site (http://www.ipc.org) "On-Line Services"
> section for additional information.
> For technical support contact Hugo Scaramuzza at [log in to unmask] or
> 847-509-9700 ext.312
> ################################################################

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################


ATOM RSS1 RSS2