In a message dated 04/03/99  01:59:50PM, you write:

>   Techneter's
>
>       We are implementing Nitrogen into our reflow ovens. Our ovens are
>       Convection Ovens. Does anyone have any knowledge or inputs that you
>       can provide me of the type of portable device that is available that
>       can be used to measure the oxygen level on the inside of the ovens. We
>       have 4 different ovens, therefore the device needs to be portable.
>
>       Appreciate any info that you can send me. Thanks

Suggest you also equip yourself with a small trolley and a long length of
pipe. Put meter on trolley and connect your pipe hangin out the front like an
old fashioned knight at a jousting session. Advance the other end of the pipe
in stages down your oven and plot your ppms. Naturally your pipe will be at
conveyor level and you will end up with a helpful prifle of ppm analgous to
your thermal reflow profile. Its interesting to see the reuslts of doing this
against N2 flow rates etc, - spots leaks, shows if you are wasting N2 by
trying to keep ppms low in unnecessary zones and so on. (also its sometimes
quite amazing when you compare ppm measured this way against that from the m/c
sampling points......)
This is a slow process so I would not build it into a daily routine.

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################


ATOM RSS1 RSS2