Hi Alejandro,
1. -10C to 65C with a heat rate of 1C/min will give you a very long test time.
This is not optimum for accelerated testing. You should be testing at about
-10C to 100C with a heat rate of 10-20C/min (not much higher to avoid thermal
shock conditions).
3. IPC-SM-785 is applicable to PBGAs, as is IPC-D-279 and ANSI/IPC J-STD-013.
Werner Engelmaier
Engelmaier Associates, L.C.
Electronic Packaging, Interconnection and Reliability Consulting
7 Jasmine Run
Ormond Beach, FL 32174 USA
Phone: 904-437-8747, Fax: 904-437-8737
E-mail: [log in to unmask]
################################################################