Pete,
The conductor to board edge clearance as specified in IPC-2222, para. 10.1.1
states minimum electrical clearance for the design plus .4mm (0.016 in.).
Regards,
Gary Ferrari
Executive Director
IPC Designers Council
860.350.9300
################################################################