Rudy,
     This is the response I sent to Les.

Les,
     What kind of tin immersion bath are you questioning?  I work with the
Omikron White Immersion Tin.  In the case of Omikron you would keep the copper
concentration under 4,000 ppm.  In most cases under normal use the
concentration will stay below 1,000.
     If you cool the bath and filter it with a one micron filter you will find
the bath stays within limits fairly easy.

Stephen M. Wentz
Florida CirTech

################################################################