Subject: | |
From: | |
Reply To: | TechNet E-Mail Forum. |
Date: | Mon, 8 Feb 1999 18:22:57 -0600 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
I hope this reply comes close to what is being discussed. Over the past year, especially, I have
used three different repair/rework machines (Conceptronic, Pace, and now SRT). Recently, I have seen
the phenomonon with PBGA's and perimeter BGA's (432 balls).
I just keep in mind that either way you look at BGA balls, they are attached to a PCB. That is,
after reflow, BGA balls are wetted and soldered to a PCB. During device assembly, they are attached
to the device PCB. Process management requirements are nearly the same for both. I mean the BGA PCB
must be solderable as well as the board. If not, non-wetting is the effect.
Earl Moon
################################################################