Hi ryu,
I hope this will be of some guidence for you.
For microstrip tracks (single transmission line on the outer
surface of the substrate with a ground plane on the reverse side)
at microwave frequencies I have always used the following rule of
thumb;
NOTHING CLOSER THAN 3 x TRACK WIDTH
Regards,
Barry Bates
> -----Original Message-----
> From: ryu [SMTP:[log in to unmask]]
> Sent: 24 February 1999 16:19
> To: [log in to unmask]
> Subject: [TN] electrical clearance
>
> *** WARNING ***
>
> This mail has originated outside your organization,
> either from an external partner or the Global Internet.
> Keep this in mind if you answer this message.
>
>
> I saw the term in the IPC-610. I think it has something to do
> with the
> design of a product for cross talk elimination. But can
> someone tell me
> if there is a minimal or maximum requirement for the distance,
> is there
> any number a designer needs to follow? if the answer is no,
> then how the
> designer comes up with the number ? Thanks.
>
> ###############################################################
> #
> TechNet E-Mail Forum provided as a free service by IPC using
> LISTSERV 1.8c
> ###############################################################
> #
> To subscribe/unsubscribe, send a message to [log in to unmask]
> with following text in the body:
> To subscribe: SUBSCRIBE TechNet <your full name>
> To unsubscribe: SIGNOFF TechNet
> ###############################################################
> #
> Please visit IPC's web site (http://www.ipc.org) "On-Line
> Services" section for additional information.
> For technical support contact Hugo Scaramuzza at [log in to unmask]
> or 847-509-9700 ext.312
> ###############################################################
> #
################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe: SUBSCRIBE TechNet <your full name>
To unsubscribe: SIGNOFF TechNet
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################
|
|
|