Depends on via sizes and quantities (totally exposed thermal plane preferred)? Also, as you were
proceeding, even the next layer down (through prepreg, laminate, and core material) provides a
thermal blanket. Obviously, this inhibits thermal transfer but, depending on size and numbers of
vias, "forces" thermal transfer through the vias to the extent maximum transfer is effected.

Another way to do the deed is to make bare the MLB edges to the extent the internal heat sink is
exposed to air or a thermal transfer interface. The interface would be a "card" guide, as an
example. Exposing, say, a .125" perimeter of bare copper would ensure more effective heat sinking
and thermal transfer. In some avionics designs, the method is called a "cold" wall.

Earl Moon

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################


ATOM RSS1 RSS2