Jon,
Our Omegameter manual recommends 14.o ug/sq. in. too, but you may consider tighter standards to achieve
Bellcore TR-NWT-000078 cleanliness standards.  It might be better to use.... say 6.5 ug/sq.in. as your
pass/fail criteria to achieve this.  Hope this helps.

Rob Watson
Sanmina Corp. Plant 10

Jon Cruz wrote:

> Hi!
>
> We have an ionic contam test here in our company and I was wondering
> if you have a specs list of what is the acceptable
> contamination level. Here, we use a Pass/Fail limit of 14.0 ug/sq.
> in. I am no tsure if this is too low or too high.
> Can you please share some info on this.
>
> Thanks.
>
> Jon Cruz
> Supervising Product Engineer
> Electronic Assemblies Inc.
> [log in to unmask]
> tel.# 823-7317/7593884
> fax# 8238326
>
> ################################################################
> TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
> ################################################################
> To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
> To subscribe:   SUBSCRIBE TechNet <your full name>
> To unsubscribe:   SIGNOFF TechNet
> ################################################################
> Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
> For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
> ################################################################

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################


ATOM RSS1 RSS2