Dave,
we are having 3 IS Pumiflex in the plant and they are all very reliable. 

We have been using a Pumiflex before innerlayer imaging, where we processed down to 0,1 mm core. But then the machine has to be very well maintained. From 0,2 mm core and above is never a problem.

The Pumiflex machines is very reliable, they are running on 4 shifts, approx. 2.000 sqm./week
Once a day we exchange pumice, approx. duration 15 min.
Once a week the brushes has to be exchanged and this last approx. 1-2 hour.
Cleaning of rinses and drying sections once a week, approx. 1 hour. 
Miscellaneous maintenance; approx. 8 hours every half year.

Hope some of this will help you ...

_______________________________________________________________________________________
Jan Thuesen
Process Engineer
Chemitalic A/S
Egebjergvej 128
DK-8700 Horsens

Tlf.: ++45 76 28 70 00
Fax:++45 76 28 70 95

Mailto: [log in to unmask]

http://www.chemitalic.com


-----Oprindelig meddelelse-----
Fra:    Modular Components National, Inc. [SMTP:[log in to unmask]]
Sendt:   11. januar 1999 15.41
Til:    [log in to unmask]
Emne:   [TN] PUMICE SCRUBBER

Hi, netters
We are looking into purchasing a I-S Pumiflex Jet Pumice Scrubber Machine. I have a couple of questions I would like to ask you guys.
1.      What do you think about I-S, how do they stack up against there competitors?
2.      We want to use this equipment to clean are boards prior to image and were wondering how thin the material can be?
3.      How reliable is this type of equipment, and how much maintenance is required to keep this type of equipment running?

I would like to thank you guys in advance for your input.
DAVE BLEVINS
Modular Components National, Inc.
2302 Industry Court
Forest Hill, MD 2150
PH (410) 879-6553
Fax (410) 838-7629

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################


ATOM RSS1 RSS2