TECHNET Archives

January 1999

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Gary Ferrari <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Fri, 8 Jan 1999 18:02:02 EST
Content-Type:
text/plain
Parts/Attachments:
text/plain (28 lines)
Frank and Earl,

Don't forget that if you must place construction characteristics such as line
widths, and thicknesses on the drawing, make them for reference. The primary
concern is that the impedance of the transmission line falls within the stated
tolerance, not the individual features. Fabricators must tweak these features
to match their process capabilities while meeting the final impedance
requirement.

Regards,

Gary Ferrari
Executive Director
IPC Designers Council
860-350-9300

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################


ATOM RSS1 RSS2