Hi all,
Just wondering if anyone is familiar with Panasonic MV100 pick and place
machine, and if you have the same problems we have. It seems like we
spend more time teaching the machine than actual time spent  running
product. The placement is not the best and techs tell me it the best
they can do. The other issue is not repeatable. What I mean is when we
need to run this product again a few weeks down the road the techs need
to re teach again!  Is this normal? Is it the Machine or the Techs? I
don't seem to have this problem with the other machines, MV2 or MPA 80.
This has been a problem since day one! Any suggestions?

Angie Marques
Quadrus Manufacturing
SR. Process Engineer
408-918-5045
[log in to unmask]

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################


ATOM RSS1 RSS2