Hi Howard,
You did not say for what PCB applications you want to evaluate the copper
foil. What is important to you? A good start is IPC-MF-150, except for
ductility. For that you need to test according to IPC-TM-650, Test Method
2.4.2.1, "Flexural Fatigue and Ductility, Foil."

Werner Engelmaier
Engelmaier Associates, L.C.
Electronic Packaging, Interconnection and Reliability Consulting
7 Jasmine Run
Ormond Beach, FL  32174  USA
Phone: 904-437-8747, Fax: 904-437-8737
E-mail: [log in to unmask]

################################################################