Mike,

A thermal relief on inner layers for surface mount connects is still used by
those concerned with field removal of components. The removal process uses a
hot air hood. The heat sinking effects of a straight connection over-rides the
heat transfer of the hot air removal system. Thereby making it difficult if
not impossible to remove the component.

Regards,

Gary Ferrari